SMT Equipment

  • X8200 X-Ray inspection system
X8200 X-Ray inspection system

X8200 X-Ray inspection system

  • x8200
  • Product description: X-Ray inspection system
  • INQUIRY
Application
BGA , CSP , Flip Chip, LED , Fuse, Diode, PCB
Semiconductor , Battery Industry , Small Metal Casting, Electronic Connector Module, Cables,

Aerospace Components, Photovoltaic Industry

Feature:
• 90kV 5µm closed X-ray tube, 4/2”image intensifier with 2 mega pixels CCD camera
• Multi-function workstation with ±60° tilt and X-Y multi-axis movement
• X-ray tube & detector automatic lifting and descending, with convenient target point positioning system
• Multi-function DXI image processing system, CNC programmable detection
• Max. loading area 510mm*420mm, max. inspection area 435mm*385mm, with 600X Magnification

X-Ray Inspection Images

Technical Specifications

Item

Description

Specifications

X-Ray Tube

Max. Voltages, Type

90kV, Closed

Power Consumption

8W

Focal Spot Size

5 μm

Motion range (Up and Down)

150mm

Magnification

600X

Detector

Intensifier

4”/2” (FPD Optional)

Resolution

77/110 LP/cm

Camera

2 Mega Pixel CCD

Motion range (Up and Down)

290mm

System Computer

Operating System

Industrial PC, Win 7, i7 Processor

Monitor

22” LCD

Software

User Interface

Unicomp Multi-function DXI image processing system

Working Platform

Max. Loading Area

510mm×420mm

Max. Inspection Area

435mm×385mm

Max. Loading Weight

10kg

Movement Control

Joysticks, Mouse and Keypads

Table Tilting Angle

±60°

Navigation

Camera

HD Camera, Laser point

Axis

Manipulator

5-axis with X / Y / Z1 / Z2 / T

Equipment Features

Power Supply

AC 110~220V (±10%) 50Hz, 1.0kW

Outline Dimensions

1080(W)×1180(D)×1730(H)mm

System Weight

1150 kg

Optional Accessories

1.Barcode Scanner; 2.Dimension Measurement Gauge

Warranty

One year warranty, free replacement the parts due to original manufacturer's defect, but expect of man-made damages and force majeure

X-Ray Safety: All X-ray machines meet the FDA-CDRH Regulation CFR 21 1020.40 Subchapter J for cabinet x-ray systems. The FDA - CDRH standard for cabinet x-ray systems states that radiation emission will not exceed. 5millirem a /hr.2"from any external surface. Our machines (Leakage <1μSv/h) are typically 5-10 times less than the international standards

CATEGORIES

CONTACT US

Contact: Minder Hu

Phone: 0086-15813334038

Tel: 020-84789496

Email: md@minder-hightech.com

Add: 813,No.43,Xinshuikeng Section, Shixin Road, Dalong street,Panyu District,Guangzhou. Zip:511442