Language: Chineseline English

Coin cell battery labrotary line

  • Single station glove box
Single station glove box

Single station glove box

  • MD-STX-A1
  • Product description: Single station glove box
  • INQUIRY

Box size: length 1220*width 750*height 900mm

Total equipment size: length 2000*width 805*height 1880mm

一、Cabinet technical parameters:

Model

Box size mm

(Length×Width×Height)

Total equipment size mm

(Length×Width×Height)

Remarks

MD-STX-A1

≈1220×750×900

≈2000×805×1880

Single-piece, single-sided 2 gloves;

Box material: SUS304 stainless steel,

 thickness 3mm.


二、Basic configuration:

Configuration and quantity

Technical parameter

Remarks

1 set of material transition cabin

390mm in diameter, 600mm in length

(The diameter is enlarged to facilitate the placement of items)

Location: the right side of the box;

Cabin material: SUS304 stainless steel;

Door cover material: aluminum alloy;

Inside the cabin: there are movable drawers;

Opening method of door cover: spinning airtight;

Can withstand vacuum: <100Pa.

1 set of tool transition cabin

150mm in diameter, 360mm in length

(The diameter is enlarged to facilitate the placement of items)

Location: the right side of the box;

Material of cabin body and door cover: 

 SUS304 stainless steel;

Door opening method: buckle type;

Can withstand vacuum: <100Pa.

1 set of rack

800~900mm in height, adjustable

Movable and fixed

1 set of shelves

Back-mounted

Double layer can be removed when not in use to save space

1 transparent visual panel

Material:Double-layerlaminated steel

Thickness: 12mm (thickening type)

Advantage:

If the glass is broken, it will not splash, will not hurt the materials in the box or the operators, and the low humidity and low oxygen atmosphere in the box will not be destroyed immediately.

2 gloves

Material: butyl synthetic rubber

Thickness: 0.4mm

Brand: American NORTHold brandQuality assurance

2 glove holes

Material: PPS (polyphenylene sulfide)

Resistant to acid and alkali; it is manufactured with one-time forming mold.

1 set of power socket

Location: Inside the box

Parameters: 220V, 10A, porous

Provide power for the equipment inside the cabinet.

1 set of lighting system

Brand: Philips

Configure fluorescent tube or LED

3 sets of spare interfaces

KF40, equipped with quick connector

Material: SUS304 stainless steel.

Installation location: the left side of the box or the location specified by the customer.

2 HEPA filters

Filter accuracy 0.3μm

Installed in the box to absorb dust.

2 vacuum gauges

Mechanical dial display

Range: -0.1~0MPa

Measure the vacuum degree of the material transition cabin and tool transition cabin.

1 pressure gauge

Mechanical dial display

Range: 0~4000Pa

Measure the air pressure of the cabinet;

In the event of a power failure, the internal pressure of the box can also be measured and displayed.

1 pressure sensor

-2500~2500Pa (relative pressure)

Touch screen display (to achieve automatic protection of the system when the pressure is too high or too low).

1 foot controller

Double pedal

Control the gas replenishment and emptying of the box.

1 gas purification system

Single purification column, model: GP25S (copper catalyst 7.5kg, molecular sieve 7.5kg, all imported materials)

Function: In addition to water and oxygen;

Installation location: below the material transition cabin or below the box (all-in-one);

Main internal components:

Fan: 90m³/H, brand: Taiwan Dagang.

Solenoid valve (auxiliary valve): G 3/8, brand: Proudly.

1 set of control system

Color touch screen: 7 inches

Touch screen, PLC brand: SIEMENS;

Chinese (including traditional), English, and Russian operation interface can be switched freely.

1 vacuum pump

Oil mist filter

Model: GVD8

Air extraction volume 8m³/H, brand: Atlas (others are optional)

1 water probe

0~1000ppm accuracy±2%FS display accuracy 0.1ppm

Touch screen display, brand: Holland STORK

Oxygen transmitter 1

0~1000ppm accuracy±2%FS display accuracy 0.1ppm

Touch screen display, oxygen sensor: American AII fuel cell type (In addition, German Schutz ZrO2 type is optional. For R&D projects, it is not recommended to choose because of the greater influence of acid and alkali gases, and the large offset is not reliable)

1 set of organic solvent filter

17L

Installed on the glove box pipeline, internal filling: efficient activated carbon.



Glove box-technical indicators

1.Technical index

Water content in the box under standard conditions

(Note: The standard situation is one atmosphere, 25℃±5℃)

≤1ppm

Oxygen content in the box under standard conditions (Note: The standard situation is one atmosphere, 25℃±5℃)

≤1ppm

Leakage rate of cabinet (Note: The standard situation is one atmosphere, 25℃±5℃)

≤0.001vol%/h oxygen (can be used as acceptance standard)

Acceptance method:

(1)       After replacing with 99.999% inert gas source, the purification system is turned on, and the water and oxygen content in the box is ≤1ppm (subject to the data displayed on the touch screen).

(2)       After the glove box reaches water and oxygen ≤1ppm, close the gas purification system: the water and oxygen content in the box rises ≤10ppm/H, which is regarded as reaching a leakage rate of ≤0.001vol%/h.

2.Functions realized by the system:

l  Hand/automatic control cabinet pressure;

l  Purification status of hand/automatic control system;

l  Automatically control the reduction process of the gas purification system;

l  Operation errors and warning prompts of the program control system;

l  System control parameter setting;

l  Check system history;

l  Working condition detection of system actuator;

l  The touch screen displays the pressure value, water content value and oxygen content value of the box instantly.

lReduction and regeneration: Purification materials that can be restored and regenerated are used in the purification system, and the reduction process is automatically controlled by the system; power supply and a mixture of hydrogen (5-10%) and inert gas must be provided during reduction and regeneration.

3.Power requirements for the glove box (2 power ports are required in total):

The first one: 220V 16A (to provide power for the glove box).

The second one: 220V 10A (provide power for the power socket in the glove box).


battery cell making machine

battery cell producing machine

CATEGORIES

CONTACT US

Contact: Minder Hu

Phone: 0086-15813334038

Tel: 020-84789496

Email: md@minder-hightech.com

Add: 813,No.43,Xinshuikeng Section, Shixin Road, Dalong street,Panyu District,Guangzhou. Zip:511442