Language: Chineseline English

Battery multifunctional testing system

  • MDBTS-5V20A battery multifunctional tester
  • MDBTS-5V20A battery multifunctional tester
MDBTS-5V20A battery multifunctional testerMDBTS-5V20A battery multifunctional tester

MDBTS-5V20A battery multifunctional tester

  • Product description: MDBTS-5V20A battery multifunctional tester
  • INQUIRY

MDBTS-5V20A battery multifunctional tester

Advantages and characteristics:

Independent charging and discharging process settings.

The equipment accuracy is 0.05%, and the data recording time is 1 second/time,

The fastest is 0.1 second/time, and the stability is high.

The software has powerful functions and friendly man-machine interface.

Four-wire system test interface to ensure high measurement accuracy.

Modular design concept, easy to maintain.

Test fuction:

1,Cycle life testing.

2,Charge and discharge characteristic test.

3,SOC maintain ability testing.

4,Overcharge and over-discharge rate affordability test.

5,voltage test.

6,temperature test.

7,maganification test.

8,Dynamic and static SOC test.

Device model

MDBTS-5V20A

Single channel

Output power

100W

communication method

TCP/IP (Network port)

Discharge voltage

5V-0.8V

Charging voltage

DC0-5V

data record

100mS~65535 S

Recharging current

5Vseries:0.02A~20A

Discharge current

5Vseries:0.02A~20A

Current accuracy

±(0.05%RD+0.05%FS)

Voltage accuracy

±(0.05%RD+0.05%FS)

Voltage resolution

When the lmV device detects or sets the voltage The smallest unit used

Electric current resolution

1mA device is detecting or setting voltage The smallest unit used

Charging mode

Constant current charging Constant voltage charging Constant power charging

Discharge mode

Constant current dischargeConstant power discharge

Charging cut-off

condition

Voltage,current,time, capacity,temperature

Discharge cut-off

condition

Voltage,current,time,capacity,temperature

5V20A Battery testing equipment

Mainly used for:soft pack polymer battery, cylindrical battery

The star of 3C test equipment, with high response, high precision, high sampling and other performance characteristics,simpie structure and modularization.

A single test device is designed for 8 channels,each Channel independent programming,and supports254 working steps at most,and the time error of the working steps does not exceed 5Oms.

Test mode support:

Constant current charging, constant voltage charging, constant current and constant volitage charging.constant power charging.Constant current discharge,constant power discharge.

Input power

AC220±10%/50Hz(Cabinet power supply mode: three-phase five-wire)

Main temperature

According to a particular apparatus 1 channel per channel optional

input resistance

≥10MQ

Current response time

Current rise time≤50mS

Power accuracy

±(0.05%RD+0.05%FS)

Number of steps in a single cycle

≤100step,With nested loop function

Circuit configuration

Modular structure design, easy replacement and maintenance

VCELL,TCELL

Optional auxiliary temperature, auxiliary voltage, single module 8 channels, can be arbitrarily mapped to each main channel Temperature range: -40~140°(Voltage range: 0~5V/0~20V)


performance

index parameter

Input power

AC220V ±10%/50Hz


Voltage

Measuring range

0.75~5V

Output range

10mV~5V

Precision

±0.1%*FSR

Output accuracy

±0.1%*FSR


Current

Measuring range

0~20A

Output range

50mA~20A

Measurement accuracy

±0.1%*FSR

Output accuracy

±0.1%*FSR


Power

Measuring range

0~900W

Output range

0~900W

Measurement accuracy

±0.2%*FSR

Output accuracy

±0.2%*FSR


Data probability

Sampling rate

1HZ:1 samples/sec

Recording rate

1HZ:1 point/sec

Recording conditions

▲T▲I▲V▲temp

Full-scale current response time

≤30ms

Time resolution

1s

input resistance

≥1MOhm

Support charge and discharge type

Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, constant load discharging, constant power discharging, support channel paralleling

Number of test commands

399 commands can be set, 65535 loops can be set, 5 levels of nested loops are supported

communication method

Ethernet,100Mbps

safety protection

hardware

Add anti-reverse connection module to prevent battery reverse connection

software

1 Power-down data protection

2Support the setting of protection conditions: voltage upper limit, voltage lower limit, current upper limit, current lower limit, capacity upper limit, energy upper limit, voltage change rate, delay protection, temperature upper limit, temperature lower limit

Calibration frequency

≥1year

Fan noise

≤85db

Number of channels per chassis

8aisles

CATEGORIES

CONTACT US

Contact: Minder Hu

Phone: 0086-15813334038

Tel: 020-84789496

Email: md@minder-hightech.com

Add: 813,No.43,Xinshuikeng Section, Shixin Road, Dalong street,Panyu District,Guangzhou. Zip:511442