MDBTS-30V60A battery multifunctional tester
Advantages and characteristics:
Single point is independent, can be carried out for each battery test channel
Independent charging and discharging process settings.
The equipment accuracy is 0.05%, and the data recording time is 1 second/time,
The fastest is 0.1 second/time, and the stability is high.
The software has powerful functions and friendly man-machine interface.
Four-wire system test interface to ensure high measurement accuracy.
Modular design concept, easy to maintain.
Test fuction:
1,Cycle life testing.
2,Charge and discharge characteristic test.
3,SOC maintain ability testing.
4,Overcharge and over-discharge rate affordability test.
5,voltage test.
6,temperature test.
7,maganification test.
8,Dynamic and static SOC test.
Device model |
MDBTS-30V60A |
Single channel Output power |
15W |
communication method |
TCP/IP (Network port) |
||
Discharge voltage |
30V-0.8V |
Charging voltage |
DC0-30V |
data record |
100mS~65535 S |
||
Recharging current |
30Vseries:0.02A~60A |
Discharge current |
30Vseries:0.02A~60A |
||||
Current accuracy |
±(0.05%RD+0.05%FS) |
Voltage accuracy |
±(0.05%RD+0.05%FS) |
||||
Voltage resolution |
The smallest unit used by 1MV equipment when detecting or setting voltage |
||||||
Electric current resolution |
The smallest unit used by 1MV equipment when detecting or setting voltage |
||||||
Charging mode |
Constant current charging, constant voltage charging, constant power charging |
||||||
Discharge mode |
Constant current discharge, constant power discharge |
||||||
Charging cut-off condition |
Voltage,current,time, capacity,temperature |
Discharge cut-off condition |
Voltage,current,time,capacity,temperature |
||||
30V60A battery testing equipment
Mainly used for:soft pack polymer battery Cylindrical battery
The star product in the 3C tester, with high response, high precision, high sampling and other performance characteristics, simple structure and modularization
A single test device is designed for 8 channels, each Channel independent programming, and supports 254 working steps at most, and the time error of the working steps does not exceed 50ms.
Test mode support:
Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging. Constant current discharge, constant power discharge.
Input power |
AC220±10%/50Hz (Cabinet power supply mode: three-phase five-wire) |
||
Main temperature |
1 channel per channel can be selected according to the specific equipment |
||
input resistance |
≥10MQ |
||
Current response time |
Current rise time≤50mS |
Power accuracy |
±(0.05%RD+0.05%FS) |
Number of steps in a single cycle |
≤100step,With nested loop function |
||
Circuit configuration |
Modular structure design, easy replacement and maintenance |
||
VCELL,TCELL |
Optional auxiliary temperature, auxiliary voltage, single module 8 channels, can be arbitrarily mapped to each main channel Temperature range: -40~140° (Voltage range: 0~5V/0~20V) |
performance |
index parameter |
||
Input power |
AC220V ±10%/50Hz |
||
Voltage |
Measuring range |
0.75~30V |
|
Output range |
10mV~30V |
||
Precision |
±0.1%*FSR |
||
Output accuracy |
±0.1%*FSR |
||
Current |
Measuring range |
0~60A |
|
Output range |
50mA~20A |
||
Measurement accuracy |
±0.1%*FSR |
||
Output accuracy |
±0.1%*FSR |
||
Power |
Measuring range |
0~900W |
|
Output range |
0~900W |
||
Measurement accuracy |
±0.2%*FSR |
||
Output accuracy |
±0.2%*FSR |
||
Data probability |
Sampling rate |
1HZ:1 samples/sec |
|
Recording rate |
1HZ:1 point/sec |
||
Recording conditions |
▲T ▲I ▲V ▲temp |
||
Full-scale current response time |
≤30ms |
||
Time resolution |
1s |
||
input resistance |
≥1MOhm |
||
Support charge and discharge type |
Constant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, constant load discharging, constant power discharging, support channel paralleling |
||
Number of test commands |
399 commands can be set, 65535 loops can be set, 5 levels of nested loops are supported |
||
communication method |
Ethernet,100Mbps |
||
safety protection |
hardware |
Add anti-reverse connection module to prevent battery reverse connection |
|
software |
1 Power-down data protection 2Support the setting of protection conditions: voltage upper limit, voltage lower limit, current upper limit, current lower limit, capacity upper limit, energy upper limit, voltage change rate, delay protection, temperature upper limit, temperature lower limit |
||
Calibration frequency |
≥1year |
||
Fan noise |
≤85db |
||
Number of channels per chassis |
8aisles |
联系人:胡顺语
手机:0086-15813334038
电话:020-84789496
邮箱:md@minder-hightech.com